OV Protection
Over-voltage protection disables the output if the output voltage reaches the OVP level.
Press
OVP State On
to enable over-voltage protection. This is the default state.
Press
OVP State Off
to disable over-voltage protection.
To set the over-voltage protection, enter an over-voltage value in the OV Protection field.
The power supply’s OVP circuit will program the output to zero whenever the overvoltage condition occurs. If
external voltage source such as battery is connected across the output, and the overvoltage condition inad-
vertently occurs, the current from the voltage source will sink through the internal circuitry; possibly dam-
aging the power supply. To avoid this, a diode must be connected in series with the output as shown below.
OC Protection
With over-current protection enabled, the power supply disables the output if the output current reaches the
current limit setting, which causes a transition from CV to CC mode.
Press
OCP State On
to enable over-current protection.
Press
OCP State Off
to disable over-current protection.
You can also specify a delay to prevent momentary CV-to-CC status changes from tripping the OCP. The delay
can be programmed from 0 to 3600 seconds. You can specify if the start of the delay is initiated by any trans-
ition into CC mode, or only at the end of a settings change in voltage, current or output state.
70
Keysight E36200 Series User's Guide
Содержание E36200 Series
Страница 1: ...User s Guide E36200 Series Autoranging DC Power Supplies ...
Страница 24: ...Dimension diagram E36231A E36232A and E36234A dimensions 24 Keysight E36200 Series User s Guide ...
Страница 34: ...Front panel Rear panel 34 Keysight E36200 Series User s Guide ...
Страница 125: ...Guide d utilisation Série E36200 Alimentations CC à commutation automatique de plage ...
Страница 148: ...Schéma de dimensions Dimensions de E36231A E36232A et E36234A 24 Guide d utilisation de la série Keysight E36200 ...