P25 Data Packet Communication During a Scan (P25 Data Channel for Scan) (P25
Conventional System Only)
P25 Data Channel for Scan
is the function to execute P25 Data Packet communication of P25 OTAR during a scan. (Refer
to
The transceiver performs the reception behavior as below according to the configuration in
Type
of
P25 Data Channel for
Scan
.
Table 6-7 P25 Data Channel for Scan Type
Configuration
Description
None
The transceiver does not receive the P25 Data Packet during a scan.
Fixed
The transceiver receives the P25 Data Packet on a Zone-channel configured by KPG-D1/ D1N
during a scan.
Selected
The transceiver receives the P25 Data Packet on a selected channel during a scan. However, if
the selected channel cannot be used due to an error state, the transceiver does not receive the
P25 Packet Data.
Note
0
Audio can also be received by using
P25 Data Channel for Scan
.
0
Dwell Time
is activated after the transceiver sends packet data.
Dropout Delay Time
is activated after the transceiver
receives packet data.
0
A text message, GPS data, or OTAP control data is sent on a Revert Channel during a scan.
0
If “None” or “Selected” is configured in
Type
of
P25 Data Channel for Scan
, a Rekey Request is sent on the selected
channel. If “Fixed” is configured in
Type
of
P25 Data Channel for Scan
, a Rekey Request is sent on the Zone-channel
configured by using KPG-D1/ D1N.
Configuration using KPG-D1/ D1N
0
Configuring
P25 Data Channel for Scan
(Single Scan) (
Transceiver Settings > Zone/Channel > Zone Edit >
Scan > Single Scan)
0
Configuring
P25 Data Channel for Scan
(Multi-Zone Scan) (
Transceiver Settings > Scan > Multi-Zone Scan)
0
Configuring
P25 Data Channel for Scan
(Scan List) (
Transceiver Settings > Scan > Scan List > Options)
6 SCAN
6.8 Scan Function
P25 FUNC (K)/Ver 2.20
225