Status List
When using Status, the Status to be sent must be preconfigured in the transceiver using KPG-D1/ D1N. A maximum of 240
statuses can be configured in the Status List. A maximum of 32 Status Lists can be registered.
Table 2-15 Status List
Configuration
Description
Status
The status number can be configured. The status number can be configured by using a number
between 1 and 240.
Status Name
The status number can be configured. It is not easy to recognize the meaning of a status only by
viewing a status number. In this case, a user can link the status number to a short message; hence,
it can be easily understood. A maximum of 16 characters can be configured.
Note
The same Status List needs to be configured also in the system.
Status Query
Status Query is the function to query the status of the transceiver. This function supports only the response behavior when
the transceiver receives a Status Query message and does not support the behavior when the transceiver queries the status
of another transceiver.
When the transceiver receives a Status Query message, the last transmitted status is automatically transmitted.
Status Message Stack
Status Message Stack
is the function to store a Status Message in the stack memory. A maximum of 250 Status Messages
and Caller IDs in total can be stored in the stack memory of the transceiver.
If a message is stored in the transceiver, the transceiver blinks the “
” icon for notification. In this case, a user can read
the stored Status Message if the transceiver enters Stack Mode. (Refer to Common FUNC
Configuration using KPG-D1/ D1N
Configuring
Status Message Stack
(
Transceiver Settings > P25 > P25 Information > General > Stack)