Conditions to Resume the Scan (Multi-Zone Scan)
One of the following conditions must be satisfied to resume the Multi-Zone Scan while the transceiver pauses the scan:
0
When a total of two or more channels targeted to be scanned exists in the zone targeted to be scanned
0
When only one target zone exists, and when one target channel exists in the target zone and a Priority Channel exists
in the target zone or another zone
0
When Priority Channel 1 and Priority Channel 2 exist in another zone, even if no zone to be scanned exists
If the transceiver does not satisfy the conditions to resume the scan, the scan remains paused.
Transceiver Behavior in the Case that the Scan Cannot Be Resumed (Multi-Zone
Scan)
If the transceiver manually switches during the scan to the zone or channel which does not satisfy the condition to resume
the scan, the transceiver displays the selected channel and the scan remains paused.
If the
PTT
switch is pressed while the condition to resume the scan is not satisfied, the transceiver transmits on Revert
Channel. Upon elapse of the time configured in
Dwell Time
after completion of the transmission, the transceiver reverts to
the selected channel, and the scan does not resume.