![Kenwood NX-5000 series Скачать руководство пользователя страница 235](http://html.mh-extra.com/html/kenwood/nx-5000-series/nx-5000-series_manual_1956164235.webp)
6.6
Priority Monitor Scan (P25 Trunking system only)
Priority Monitor Scan is the scan for a P25 Trunking system, and when a voice communication of higher priority is initiated
while receiving on a normal channel, this function can switch on the traffic channel to the voice communication (on the
Priority Channel).
In order to use this function, the system must be configured to send a message including Group Call information on the
traffic channel. The transceiver determines based on this information whether or not to migrate to the Priority Channel.
0
Single Scan
A maximum of 2 Priority Channels can be configured in each zone.
0
List Scan
A maximum of 2 Priority Channels can be configured in each Scan List.
Priority Channel Type (Type)
Priority Channel Type can be selected from “None”, “Fixed”, “Selected” and “Operator Selectable”.
Table 6-4 Type
Configuration
Description
None
No Priority Channel is configured.
Fixed
The channel configured using KPG-D1/ D1N is configured as the Priority Channel. The Priority
cannot be changed by operating the transceiver.
Selected
The channel selected on the Transceiver is configured as the Priority Channel.
Operator Selectable
The channel configured by a user in Priority-channel Select Mode (Single Scan) is configured as
the Priority Channel. (Refer to
.)
Transceiver behavior
0
If the Zone-channel configured for the Priority 1 is selected, or if the scan is paused on the Zone-
channel configured for the Priority 1
The “ ” icon appears.
Menu
Zone+
Z o n e 1
T a l k g r o u p 1
12 : 34
A
M
6 SCAN
6.6 Priority Monitor Scan (P25 Trunking system only)
P25 FUNC (K)/Ver 2.20
215