The transceiver emits the received audio from the speaker if the received Optional Signaling matches the Optional
Signaling preconfigured for the transceiver while waiting to receive the Optional Signaling. After the Optional Signaling
matches, the transceiver waits to receive on the channel where the transceiver received the Optional Signaling.
Reception Behavior during the Scan in a P25 Trunking System
During the scan, the transceiver waits for Group Calls from multiple Talkgroups on a control channel. When a Group Call
for the Talkgroup of a channel to be scanned is received, the transceiver stops scanning and migrates to a traffic channel.
The transceiver can activate the Priority Monitor Scan until the transceiver returns to the control channel after migrating to
the traffic channel. (Refer to
Priority Monitor Scan (P25 Trunking system only)
.)
Transceiver behavior when receiving an Individual Call or Group Call during the Scan
If the transceiver receives an Individual Call or Group Call during the scan, the scan resumes at the following timings
according to the configurations in
Dropout Delay Time
and
Auto Reset Timer
:
0
If the time configured in Auto Reset Timer is longer than the time configured in Dropout Delay
Time
When the time configured in
Auto Reset Timer
elapses, the reception display for Individual Call or Group Call is disabled
and the scan resumes. When the time configured in
Dropout Delay Time
elapses, the scan does not resume.
0
If the time configured in Auto Reset Timer is shorter than the time configured in Dropout Delay
Time
When the time configured in
Auto Reset Timer
elapses, the reception state for Individual Call or Group Call is disabled,
and when the time configured in
Dropout Delay Time
elapses, the scan resumes.
0
If “Off” is configured in Auto Reset Timer
Even if the time configured in
Dropout Delay Time
elapses, the scan does not resume.
6.8
Scan Function
The following functions are relevant to the scan:
0
Scan Delete/ Add
0
Zone Delete/Add
0
Revert Channel
0
Dropout Delay Time
0
Dwell Time
0
Channel Recall
0
Priority-channel Stop Tone
0
Auto Scan
0
Selected Channel Scan
0
Power-on Scan
0
Off-hook Scan (Mobile Only)
0
Scan Stop Tone
0
Preamble Length
0
P25 Data Channel for Scan
6 SCAN
6.7 Transceiver Behavior during the Scan
P25 FUNC (K)/Ver 2.20
218