KC-P30 Charging Station
Auxiliary device
V1.03
21
© KEBA
4
Auxiliary device
The following functions are part of the type examination certificate and are
tested as part of the conformity assessment procedure in accordance with
MessEV:
●
Instant display of relevant information
●
Generation of measurement data records
●
Generation of log data records
●
Remote transmission of data records
4.1
Instant display of relevant information
At the start and end of the charging process, the following information is in-
stantly displayed for the user on the charging station display:
●
Identification data for the current charging process (user/transaction ID)
●
Transmitted energy of the charging process
More specific information on the displays are described in the "Operating In-
structions."
4.2
Generation of measurement data records
For each charging session and every other mode in which energy can be
transmitted (e.g. commissioning mode or test mode), a measurement data
record is generated and signed in the measurement capsule.
Even in an error mode in which the contactor contacts have been welded, in-
correct operation with an adapter may still result in current being drawn.
Therefore, a data record is also formed here and saved locally.
> 20.000 measurement data records are saved securely in the certified mea-
surement capsule. The memory is implemented in the form of a ring buffer.
After writing to the last storage space, the oldest data record is overwritten.
The dimensioning of the memory permits the storage of data records for 10
years, at 5 charging sessions per day.
A measurement data record contains the following information:
OCMF |
{
"FV":"1.0",
"GI":"KEBA_KCP30",
"GS":"1234";
"GV":"2.8.3",
"PG":"T108",
"IS":true,
"IL":"HEARSAY",
"IF":["RFID-PLAIN", "OCPP_NONE", "IS015118_NONE", "PLMN_NONE"],
"IT":"IS014443",
"ID":"DD34EE8F",