KC-P30 Charging Station
Requirements
V1.03
20
© KEBA
●
IMEI-dependent activation of SIM cards
●
Protection of configuration interfaces (including web interface access)
●
Use strong passwords for web interface, protection of password informa-
tion
●
Use of HTTPS
●
Certificate-based communication
Connection to a network with a sufficient data rate and data
volume
●
~400 kB per transaction/data record
●
User-friendliness when reading out the measurement data
●
Installing (security) updates
Keeping a list of measurement points
The list of measurement points should have at least the following content:
●
Manufacturer material number (PN on the type plate of the charging sta-
tion)
●
Manufacturer serial number (SN on the type plate of the charging sta-
tion)
●
Public key (for the measurement capsule, pictured on the type plate of
the charging station in the form of a QR code)
●
Place of use
Clarity in the user-configurable display texts
Information relevant for calibration law is displayed by the charging station
with a special label (ME). Additional informative texts must not confuse cus-
tomers or suggest functions that are not supported by the device.
●
No rating/pricing possible in the device
●
Time-based rating not possible