KC-P30 Charging Station
Requirements
V1.03
16
© KEBA
3
Requirements
The following chapters describe the requirements for the proper operation of
the charging station in compliance with calibration law.
In the following chapters, the following terms are used:
●
User of the measurement device: The charge point operator (CPO), as
defined by § 31 of the German Measures and Verification Act (MessEG),
is the user of the measurement device.
●
User of measured values: The electromobility service provider (EMSP),
as defined by § 33 of the German Measures and Verification Act
(MessEG), is the user of the measured values.
3.1
Rated operating conditions
Use:
Inside and outside area
Access limitations at set-up location:
Limited and unlimited access
Installation (stationary):
On the wall or on a floor-mounted column.
Operating temperature:
-25 °C to +40 °C (without direct sunlight)
Storage temperature:
-25°C to +80 °C
Relative air humidity:
5% to 95% (non-condensing)
Altitude:
max. 2000 m above sea level
Rate of temperature change:
max. 0.5 °C / min
Temperature behavior:
Automatic power reduction if overheating oc-
curs
Further information can be found in the "Installation Manual."
3.2
Instructions for correct measurement in accordance with
type examination certificate
I Requirements for the operator of the charging device, who must meet
said requirements as a necessary prerequisite for the proper operation
of the charging device.
The operator of the charging device, in the terms of § 31 of the German
Measures and Verification Act, is the user of the measurement device.
1) The charging device shall only be used as intended for legal purposes
and in accordance with legal requirements if it is not exposed to environ-
mental conditions other than those for which its type examination certifi-
cate was issued.
2) When registering the charge points with the German Federal Network
Agency, the user of this product must also register the PK specified on
the charging device for the charge points in its registration form! Without
this registration, it is not possible to operate the charging device in com-
pliance with calibration law.