KC-P30 Charging Station
Auxiliary device
V1.03
22
© KEBA
"RD":[
{
"TM":"2019-06-11T12:47:43, 000+000 I",
"TX":"B",
"EF":"",
"ST":"G",
"RI":1530.6346,
"RU":"kWh"
},
{
"TM":"2019-06-11T17:09:45, 000+0000 R",
"TX":"E",
"EF":"",
"ST":"G",
"RV":1550.8650,
"RI":"1-b:1.8.0",
"RU":"kWh"
}
]
}|
{
"SD":"3045022024BD092E86BB6EABA566A0EFBB5D4E7095693C882E5453F90984A1
E1A4D1C88C02210089D35386AE9431AFDCA446B79DD8B57DD031BA3ACE0455CF2F9
D4BD9CAF165D4"
}
Description of contents
Abbr.
Designation
Description/Possible values
Device information
FV
Format and version
GI
Meter manufacturer and designa-
tion of the charging station
GS
Serial number of the meter
Where necessary, otherwise "0"
GV
Software version of the meter
Local ID of the charging session
PG
Serial number of the charging ses-
sion (pagination)
"L" + serial number per device
Identification of the charging session
IS
Status of the user assignment
true
: User assigned successfully
false
: User unassigned (e.g. authorization
is deactivated)
IL
Level of the user assignment
1
NONE, HEARSAY, TRUSTED,VERI-
FIED,CERTIFIED, SECURE
IF
Details of the user assignment
Specification of which authorization proce-
dure is used for assignment:
RFID
,
OCPP
,
ISO15118
or
PLMN
(authorization via mo-
bile network)
IT
Type of user assignment
ID
Actual identification of the charging
session
RFID UID, OCPP transaction ID, commis-
sioning mode or test mode.
RD: Start register values (top block) + End register values (bottom block)
TM
Time stamp
2
for calculating the
charging duration
3
Date:Time, synchronization state