KC-P30 Charging Station
Calibrating the device
V1.03
37
© KEBA
Fig. 6-6: Connection panel: Elements for activating/deactivating the test mode
DSW
... DIP switch
X6
... Pin strip for jumpers
Activate test mode
Information
Before the test mode is activated, the current setting of the DIP switches
should be noted so that the DIP switches can then be set back to their origi-
nal values.
Necessary aids: Jumper
To activate the test mode, proceed as follows:
1) Switch off the supply voltage of the charging station.
2) Set the jumper on the pin strip for the jumper
X6
.
3) Set the DIP switches for the charging current to 32 A:
DSW1.6
to
ON
DSW1.7
to
OFF
DSW1.8
to
ON
4) Set the DIP switch for commissioning mode
DSW2.8
to
ON
.
5) Switch on the supply voltage of the charging station.
Test mode is activated.
Deactivate test mode
To deactivate the test mode, proceed as follows:
1) Switch off the supply voltage of the charging station.
2) Remove the jumper from the pin strip
X6
.
3) Set the DIP switch for commissioning mode
DSW2.8
to
OFF
.
4) Set the DIP switches for the charging current back to the original value.