KC-P30 Charging Station
Requirements
V1.03
19
© KEBA
10) All of the duties listed above apply to the EMSP as the measured value
user in the terms of § 33 MessEG even if they obtain measured values
from the charging devices via a roaming service provider.
3.3
Additional requirements for the operator
The following additional requirements apply to the charge point operator:
●
Selection of a suitable device variant (see
)
●
Integrity of the charging station and associated components such as
charging cable, charging plug or charging socket
●
Correct installation according to the installation instructions in compli-
ance with national and regional regulations
●
Sufficient period of validity of the calibration according to the calibration
stamp. The information is visible on the type plate or on the front part
when calibrated.
●
Correct function of the display and sufficient readability of the relevant
information
●
Visibility and readability of the type plate
●
Intact meter seal on the front part with the number 3002 2073 (manufac-
turer seal)
●
Intact seal on the connection panel cover (user seal)
●
Sufficient protection of the operator infrastructure
●
Cyclical reading of the signed measurement data in order to keep fail-
ures low
3.4
Additional recommendations
For proper charging station operation in compliance with calibration law, the
following measures are also recommended:
Protection of the (network) infrastructure
Options for implementing protection of the (network) infrastructure (incom-
plete list):
Physical
●
No openly accessible connection points (power connection and network)
●
No openly accessible network cables
●
Protection of network distributors
Digital
●
Deactivate WLAN after installation
●
Use of VPN/APN
●
Use of PIN-protected SIM cards