KC-P30 Charging Station
Description of the device
V1.03
14
© KEBA
1
... Pulse LED
2.9
Active power meter
Information
The required energy for setting the charging station by the manufacturer
and for the commissioning process are part of the total energy. For this rea-
son, the meter reading will not have the value "0" after the installation has
been completed.
Information
The maximum meter reading is 99 999, after reaching this value the meter
starts from "0" again.
Counting register overflow is limited by the limitation of displayable points on
the display. Within a measurement data record (start counter status – end
counter status), there is no overflow. Resetting to "0" happens when starting
the next charging session.
2.9.1
Measurement principle
The measurement of the transmitted energy takes place by means of pas-
sive transducers on all phases to be contacted.