KC-P30 Charging Station
Calibrating the device
V1.03
35
© KEBA
●
The display shows the total energy in 0.1 Wh ("Ʃ Wh").
●
Segment S3 on the LED bar lights up orange and segment S1 flashes
green.
●
Test mode starts with a counter that is incremented by one every sec-
ond. This function allows for the timekeeping of the device to be
checked. Once energy is flowing, this is also indicated.
Information
In test mode, there is no change in the mode of operation or measurement
accuracy of the active power meter. Only the resolution of the display is
changed.
The transmitted energy in test mode is saved in a measurement data
record.
In the following table, the behavior of the charging station is compared for
modes "operation", "error", "commissioning" and "test mode."
Opera-
tion
Error
Commissioning
Test mode
ON time of contactor
-
x
10 minutes
3 hours
CP signal
(Control Pilot)
on
specific
12 V
12 V
DC residual current
detection
on
x
off
off
Contactor monitoring
on
x
on
off
Pulse LED
off
x
off
on
Resolution of the total
energy display
0.1 kWh
x
0.1 Wh
0.1 Wh
Active power meter (en-
ergy meter)
on
x
on
If energy = 0: off
(only charging dura-
tion is displayed)
If energy > 0: on
(energy is displayed)
Generation of
measurement data
records
on
on
on
on
x ... State not known in case of error