Annex for Software Version 1.32
90
These parameters allow an error correction during the positioning process in
reference to various speeds.
With EP.07 errors caused by slip (load characteristic), release delay and inaccuracies
are compensated. Parameter EP.06 makes it possible to shift the holding position
(replaces the shifting of an initiator).
The values are not standardized and must be determined empirically.
After triggering of the positioning a change can be delayed with this parameter. This
function enables the adjustment of a defined holding time in the reached position.
Correcting
factor(EP.07)
Shifting factor
(EP.06)
Set change time lock
(EP.08)
-
0
+
ε
-
0
+
ε
EP.07 = 0...32767
EP.06 = 0...32767
f / [Hz]
f
max
f / [Hz]
f
max
tdec
t konst/const
tdec
τ
t ist/set =
nmax
τ
n
max
tEP.08
Positioniersatz/positioning set