Keyboard Operation
18
The display in Drive-Mode is divided differently than in the Customer- and Application-
Mode.
Working
Condition
1st Digit
2nd - 5th Digit
STOP
set direction of rotation (F / r)
LS (noP, when ST is not active)
START
actual dir. of rot. (F / r)
actual frequency
RUN
actual dir. of rot. (F / r)
actual frequency
SPEED-display reserved
actual frequency
The Drive-mode is called up when the Driver password is entered in parameter cP.0
and/or ud.0. The initial state is STOP.
It is only possible to leave the Drive-Mode with STOP and/or START. If the keys
ENTER and FUNCT are simultaneously pressed for about 3s, then the the operating
surface changes to the display of the password (cP. 0 and/or ud. 0). The the password
level becomes active that was active before the Drive-Mode was called up.
4.4 Password Structure
The password is entered with parameter ud. 0 (Application-Mode) and/or cP. 0
(Customer-Mode).
In this case the password remains stored after Power On and must not be released
again each time the unit is switched on. There are 5 password levels of which 1 is
always active. When a new password is entered the password level changes. Inputs
that do not match a valid password are ignored.
The supervisor password is not stored when the unit is switched off. Once the unit is
switched on again the password that was valid before the service password is active.
1.
CP - READ ONLY
Only the Customer parameter group is visible.
Only CP. 0 (Password in) can be changed.
2.
CP - ON
Only the Customer parameter group is visible.
All Customer parameters can be changed.
3.
CP - SERVICE
Corresponds to the Customer password. The
parameter identification of the parameter is
shown that is assigned to the Customer
parameter.
4.
APPLICATION
All Application parameters are visible and can
be changed. The Customer group is not visible.
5.
SUPERVISOR
All parameters are visible and can be changed.
The Customer group is not visible.
6.
DRIVE - MODE
The unit is controlled by the keyboard.
Display in Drive -
Mode
Entering / Leaving
the Drive - Mode
Password Input
Password List
Содержание COMBIVERT F4-S/1.2
Страница 1: ...C O M B I V E R T APPLICATION MANUAL Control unit F4 S 1 2 ANTRIEBSTECHNIK 00 F4 SEA K120 07 99 ...
Страница 2: ......
Страница 24: ...ru Parameter 24 ...
Страница 42: ...uF Parameter 42 ...
Страница 54: ...Fr Parameter 54 ...
Страница 58: ...An Parameter 58 ...
Страница 64: ...di Parameter 64 ...
Страница 76: ...In Parameter 76 ...
Страница 94: ......
Страница 95: ...ANTRIEBSTECHNIK ...