dr - Parameter
44
The input of the correct motor data is important for many inverter functions, since
calculations are derived from it, which the inverter requires in order to achieve the
best possible results in torque- and slip compensation.
Input of the rated motor speed as directed in the type plate of the motor.
Input of the rated motor current as directed in the type plate of the motor.
Input of the rated motor frequency as directed in the type plate of the motor.
Input of the rated motor cos (phi) as directed in the type plate of the motor.
Input of the ohmic resistance between 2 phases, measured at the beginning of the
motor cable. The wiring of the motor (star, delta) must be the same as in operation.
Use suitable measuring instruments!
Input of the rated motor voltage as directed in the type plate of the motor.
dr - Parameter
Rated Motor
Speed (dr. 1)
Rated Motor
Current (dr. 2)
Rated Motor
Frequency (dr. 3)
Rated Motor cos(phi)
(dr. 4)
Motor Terminal
Resistance (dr. 5)
Rated Motor Voltage
(dr.12)