In (ru. 0) the working condition of the inverter is shown. The various displays are
explained below.
Display Value
Significance
noP
0
No Operation: control release not activated, modulation switched
off, output voltage = 0, drive not guided
E.OP
1
Over Potentional, dc-bus voltage too high
E.UP
2
Under Potentional, dc-bus voltage too low
E.OC
4
Over Current, output current > 2 * Irated (constant torque)
E.OH
8
Over Heat, overheating of the inverter
E.dOH
9
Drive Over Heat, temperature monitoring of the motor was
triggered and the delay time has run out
E.LSF
15
Ladeshunt Fault, ladeshunt not connected
E.OL
16
Over Load, overload monitoring of the inverter was triggered
E.nOL
17
No Over Load, cooling period E.OL has run out, error can be
reset
E.EF
31
External Fault, error message through external unit
A hardware error occurs if E.EF is not programmed (s. page 61).
Measure: Send unit to the repair service
E.nOH
36
No Over Heat, overtemperature error is no longer present (E.OH
or E.dOH), error can be reset
E.SEt
39
Set selection error
E.PuC
49
Power circuit identity invalid
FAcc
64
Forward Acceleration: drive accelerated forward
FdEC
65
Forward Deceleration: drive decelerates forward
Fcon
66
Forward Constant: drive runs with constant speed forward
rACC
67
Reverse Acceleration: drive accelerates in reverse
rdEC
68
Reverse Deceleration: drive decelerates in reverse
Inverter State (ru.0)
Содержание COMBIVERT F4-S/1.2
Страница 1: ...C O M B I V E R T APPLICATION MANUAL Control unit F4 S 1 2 ANTRIEBSTECHNIK 00 F4 SEA K120 07 99 ...
Страница 2: ......
Страница 24: ...ru Parameter 24 ...
Страница 42: ...uF Parameter 42 ...
Страница 54: ...Fr Parameter 54 ...
Страница 58: ...An Parameter 58 ...
Страница 64: ...di Parameter 64 ...
Страница 76: ...In Parameter 76 ...
Страница 94: ......
Страница 95: ...ANTRIEBSTECHNIK ...