ADM 6725 E10
KA
T
4 - 5
Program Branch PARAMETER
#
Stainless Steel
P5-2
#
Glass P5-3
#
Copper P5-4
#
Aluminium P5-5
#
Brass P5-6
#
Lead P5-7
#
Grey Cast Iron
P5-8
#
Ductile Iron
P5-9
#
Asbestos Cement
P5-10
#
PVC P5-11
#
PE P5-12
#
PP P5-13
#
Bitumen P5-14
#
Rubber P5-15
#
Perspex P5-16
!
Other Material
P5-17
Next display
P7
(Without pressing ENTER,
the display list scrolls around)
When a pipe material has been selected, FLUXUS jumps straight to the display for
choosing the pipe lining material. If the above list does not contain your pipe
material, the set-up can be done as follows:
Pipe Material
Other Material
"
P5-17 Scroll through to the display
'Other
Material'
.
Confirm by pressing
ENTER
.
c-Material
3200.0 m/s
P6
FLUXUS requests the entry of the sound
velocity for the pipe material.
(Table 2 in chapter
17 gives an overview of the sound velocities for some
materials.)
Enter the data of the respective material
within a range from 600 to 6553.5 m/s
and confirm by pressing ENTER.
Then the display for entering the data for the pipe
lining
material appears.
4.2.4 Pipe Lining
no >YES<
Lining
P7
Here, the instrument asks if the pipe is
fitted with lining material or not. If YES,
the following subdisplay group will be
shown.
Lining
"
P8
"
select
ENTER confirm
(The list of displayed materials can be different
as shown according to specific customer
request.)
Содержание FLUXUS ADM 6725
Страница 1: ...Operating Instructions RESET INIT 3x OFF ON PORTABLE ULTRASONIC FLOWMETER FLUXUS ADM 6725 ...
Страница 4: ...ADM 6725 E10 KAT ...
Страница 14: ...1 4 ADM 6725 E10 KAT Functional Description This page has been left empty intentionally ...
Страница 28: ...2 14 FLUXUS ADM 6725 E10 KAT Description of Flowmeter This page has been left empty intentionally ...
Страница 69: ...ADM 6725 E10 KAT 6 9 Program Branch OUTPUT OPTIONS 2700 s Storage Rate O11 6a Next display e g current loop ...
Страница 70: ...6 10 ADM 6725 E10 KAT Program Branch OUTPUT OPTIONS This page has been left empty intentionally ...
Страница 104: ...10 6 ADM 6725 E10 KAT Virtual Calculation Channels This page has been left blank intentionally ...
Страница 112: ...11 8 ADM 6725 E10 KAT Heat Quantity Measurement This page has been left empty intentionally ...
Страница 122: ...12 10 ADM 6725 E10 KAT Wall Thickness Measurement This page has been left blank intentionally ...
Страница 132: ...Process Interfaces 13 10 ADM 6725 E10 KAT This page has been left blank intentionally ...
Страница 138: ...14 6 ADM 6725 E10 KAT Errors This page has been left blank intentionally ...