Technical features
BR/BD 100/250 R BP / RI
Page 16 / 171
Service Manual 08.2007
Water filter
The water filter (2) is located on the front left-
hand side under the fresh water tank.
It filters the fresh water to protect the water pump.
Water filter
Water pump (M5) and Cleaning agent mete-
ring pump (M6)
The water pump (3) and the cleaning agent me-
tering pump (4) are located to the left at the front
next to the steering head in the direction of travel.
The water pump (3) pumps the fresh water to the
brush head.
The cleaning agent metering pump (4) pumps
the cleaning agent to the injection point in the
water inlet hose to the brush head.
Cleaning agent metering pump (M6) and water
pump (M5)
2.5 Water system
1
Shut-off valve
2
Water filter
3
Metering valve (Y2)
4
Water pump (M5)
5
Cleaning agent metering pump (M6)
(optional)
6
Cleaning agent suction hose with float
7
Space for cleaning agent canister
8
Cleaning agent canister (optional)
2
1
5
4
Cleaning agent canister (optional)
Cleaning agent canister (optional)
In the space (7) behind the driver’s seat max 2
cleaning agent canisters each with 10 litre can
be fitted.
8
6
7
3
Note
The cleaning agent metering pump (M6) is
deactivated as a standard (see Chapter 3.3.9
/ 5.3.5).
The cleaning agent metering can be
activated in the setup menu „system
parameters“ (see Chapter 5.3).
Содержание BR 100 R
Страница 1: ...Service Manual 08 2007 5 906 252 0 BR BD 100 250 R RI BR BD 120 250 R RI 1 480 Service Manual ...
Страница 2: ...BR BD 100 250 R BP RI Page 2 171 Service Manual 08 2007 ...
Страница 153: ...BR BD 100 250 R BP RI Circuit diagrams Page 153 171 Service Manual 08 2007 8 1 Circuit diagram 0 088 734 0 Head CPU A1 ...
Страница 154: ...Circuit diagrams BR BD 100 250 R BP RI Page 154 171 Service Manual 08 2007 8 2 Circuit diagram 0 088 876 0 Head CPU A1 ...