BR/BD 100/250 R BP / RI
Basic settings and service procedures
Page 91 / 171
Service Manual 08.2007
5.3 Setup menu
5.3.1.1 Access to the setup menu
Display
Battery:
E....F
Water/C:
E....F
Display
Parameter setup
menu?
yes
no
Switch program selection
switch to Pos. 1
yes
no
yes
no
10s
10s
Display
Quit parameter
SETUP?
Press i-button 3 times
within 2 sec
Yellow LED then lights up
(key symbol)
Continue to turn i-button until the
following appear
- Quit operator menu?
- Accept manufacturer
settings?
- Display contrast
min IIII --max
- Information menu
- Diagnosis information?
- Parameter setup menu
- Delete user operating
time
- Information menu
Operating notes on display
Accept manufacturer settings?
If the manufacturer settings are to be accepted,
the display must first be found using the
i-button rotary function
and then acknowledge using the
i-button inch function.
The Manufacturer settings accepted.
display then appears.
Further menu activities can then be executed
System menu and driving menu parameters
(See chapter 5.3.1.2)
Cleaning modul and lifting modul parameters
(See chapter 5.3.1.3)
Initial operation takes place in accordance with 3.3.1
Содержание BR 100 R
Страница 1: ...Service Manual 08 2007 5 906 252 0 BR BD 100 250 R RI BR BD 120 250 R RI 1 480 Service Manual ...
Страница 2: ...BR BD 100 250 R BP RI Page 2 171 Service Manual 08 2007 ...
Страница 153: ...BR BD 100 250 R BP RI Circuit diagrams Page 153 171 Service Manual 08 2007 8 1 Circuit diagram 0 088 734 0 Head CPU A1 ...
Страница 154: ...Circuit diagrams BR BD 100 250 R BP RI Page 154 171 Service Manual 08 2007 8 2 Circuit diagram 0 088 876 0 Head CPU A1 ...