BR/BD 100/250 R BP / RI
Basic settings and service procedures
Page 89 / 171
Service Manual 08.2007
5.2.3 Test mode - lifting motors
Display
TESTER-MODE
linear actuators
Switch program switch (S9) to
Pos 1 Drive
>3s
Display
TESTER-MODE
linear actuators
(flashing)
Key: Info button
Inching mode
Switch program switch (S9) to
Pos 2 Scrub-Vacuum
Switch program switch (S9) to
Pos 3 Wet-Scrub
Switch program switch (S9) to
Pos 4 Vacuum
Brush head lifting motor (M20)
Moves upwards according to the
button activation (inching mode)
until it reaches the limit position
and is switched off by:
- electronic current limiter
- microswitch (S21), provided this
function is activated in the setup
menu (Chap. 5.3).
H Brush head lifting motor (M20)
Moves downwards according to the
button activation (inching mode)
until it reaches the limit position
and is switched off by:
- electronic current limiter
- microswitch (S20), provided this
function is activated in the setup
menu (Chap. 5.3).
Suction beam lifting motor
(M30)
Moves upwards according to the
button activation (inching mode)
until the limit position
and is switched off by
the microswitch (S31).
H Suction beam lifting motor
(M30)
Moves downwards according
to the button activation
(inching mode)
until the limit position
and is switched off by
the microswitch (S30).
Note:
The microswitch function can be activated/deactivated using the system menu (Chapter 5.3, brush lifting motor).
Access to
TEST-MODE
(see chapter 5.2.1)
Содержание BR 100 R
Страница 1: ...Service Manual 08 2007 5 906 252 0 BR BD 100 250 R RI BR BD 120 250 R RI 1 480 Service Manual ...
Страница 2: ...BR BD 100 250 R BP RI Page 2 171 Service Manual 08 2007 ...
Страница 153: ...BR BD 100 250 R BP RI Circuit diagrams Page 153 171 Service Manual 08 2007 8 1 Circuit diagram 0 088 734 0 Head CPU A1 ...
Страница 154: ...Circuit diagrams BR BD 100 250 R BP RI Page 154 171 Service Manual 08 2007 8 2 Circuit diagram 0 088 876 0 Head CPU A1 ...