5.3.5 Module parameter manufacture settings
Standard parameter setup menu
Adjustments must be made by service department for
accessory kits or upgrades!
Available for PRE-SWEEPER option
Available for SIDE BRUSH option
**) IMPORTANT: These values must be changed by the produc-
tion when using a faster or slower drive motor. The access and
values will be announced when the first model is built!!
.+) The adjustment limits given are maximum values. They are
mutually interdependent as follows: t_sweep_max = t_suction_min,
and t_suction_min = t_sweep_max. this ensures that the intake
fan always runs at least as long as the sweeper. Example: Setting:
t_brush_max = 3s -> Setting t_suction_min = 3s. Setting
t_suction_max = 2s -> setting of t_sweep_max = 2s.
PARAMETER-SETUP, sequence and factory settings BR 100/250R(I) - State 2005/05/20
Module
Parameter presentation in
display
Factory setting
min:step:max
Notes
max. speed:
M2/D-S:
40%
40%
15%:5%:70%
Slow nominal speed controller for downward
travel of brush lift motor in the pressure control
phase.
Order
Service
access
Development
access
1
X
Lift module (1),
Clone 1: Controls
for suction beam
+ scrubber head
Available in:
a) Basic unit
b) Basic unit +
side brush
c) Basic unit +
pre-sweeper
max. speed:
M2/U-S:
60%
60%
15%:5%:70%
Slow nominal speed of the speed controller during
upward travel brush lift motor in the pressure
control phase.
2
X
Clean module (2),
Clone 2: Control
of the pre-sweeper
Available in:
Basic unit + pre-
sweeper
CANNOT BE ADJUSTED!
max. speed:
M2/D-S:
20%
20%
15%:5%:70%
Slow nominal speed of the speed controller during
downward travel brush lift motor in the pressure
control phase.
1
X
Lift module (2),
Clone 2: Control
of lift motor pre-
sweeper and side
brush
Available in:
a) Basic unit +
side brush
b) Basic unit +
pre-sweeper
max. speed:
M2/U-S:
60%
60%
15%:5%:70%
Slow nominal speed of the speed controller during
upward travel brush lift motor in the pressure
control phase.
2
X
Acceleation number
#) Start up
##) Braking
0.8 m/s
2
1.1 m/s
2
1.0 m/s
2
1.3 m/s
2
1.2 m/s
2
1.5 m/s
2
1.4 m/s
2
1.7 m/s
2
1.9 m/s
2
1
2
3
4
1.6 m/s
2
5
Содержание BR 100 R
Страница 1: ...Service Manual 08 2007 5 906 252 0 BR BD 100 250 R RI BR BD 120 250 R RI 1 480 Service Manual ...
Страница 2: ...BR BD 100 250 R BP RI Page 2 171 Service Manual 08 2007 ...
Страница 153: ...BR BD 100 250 R BP RI Circuit diagrams Page 153 171 Service Manual 08 2007 8 1 Circuit diagram 0 088 734 0 Head CPU A1 ...
Страница 154: ...Circuit diagrams BR BD 100 250 R BP RI Page 154 171 Service Manual 08 2007 8 2 Circuit diagram 0 088 876 0 Head CPU A1 ...