Technical features
BR/BD 100/250 R BP / RI
Page 44 / 171
Service Manual 08.2007
2.13 Pre-sweeper unit, sealing strip
1
Mounting plate, small, sealing strip
2
Sealing strip, side
3
Mounting plate, large, sealing strip
1-3 mm
(0.039 in - 0.118 in)
2
3
1
The sealing strip (2) is mounted and its height
adjusted using the retaining screws (5x, arrow).
The distance between the floor and sealing strip
(2) should be 1-3 mm (0.039 in - 0.118 in).