BR/BD 100/250 R BP / RI
Modular Electronic Control Circuits
Page 75 / 171
Service Manual 08.2007
4.8 Lifting module (A4/1) (optional) and cleaning module (A3/1)
(optional)
1
Terminal strip (X7/A3/1)
2
Terminal strip (X2/A3/1)
3
Terminal strip (X1/A3/1)
4
Programming plug (X3/A3/1)
5
Terminal strip (X4/A3/1)
6
Terminal strip (X12/A3/1)
7
Connecting terminal (X10/A3/1), suction
motor (M4)
8
Connecting terminal (X8/A3/1), brush
motor (M2)
9
Connecting terminal (X5/A3/1), battery-
negative cleaning module (A3/1)
10
Connecting terminal (X13/A3/1), brush
motor (M3)
Note:
Connections at the relevant terminal strips
and performance values for fuses - see
circuit diagram 0.088-734
Tightening torque:
M5 (press-fitted connection) (10): 2,2 Nm
M6 (press-fitted connection)
(9), (11):
3,9 Nm
M8 threaded bolt:
5,5 Nm
M10 threaded bolt:
17,0 Nm
Lifting module (A4/1), (optional)
Cleaning module (A3/1), (optional)
7
8
9
11
5
4
3
2
1
13
10
18
16
17
15
14
6
11
Connecting terminal (X6/A3/1), battery
positive cleaning module (F3)
12
Battery - negative post (Support point)
13
Printed circuit board - cleaning module
(A3/1), optional
14
Terminal strip (X2/A4/1)
15
Terminal strip (X3/A4/1)
16
Terminal strip (X4/A4/1)
17
Programming plug (X1/A4/1)
18
Terminal strip (X5/A4/1)
19
Printed circuit board - lifting module
(A4/1), optional
19
Содержание BR 100 R
Страница 1: ...Service Manual 08 2007 5 906 252 0 BR BD 100 250 R RI BR BD 120 250 R RI 1 480 Service Manual ...
Страница 2: ...BR BD 100 250 R BP RI Page 2 171 Service Manual 08 2007 ...
Страница 153: ...BR BD 100 250 R BP RI Circuit diagrams Page 153 171 Service Manual 08 2007 8 1 Circuit diagram 0 088 734 0 Head CPU A1 ...
Страница 154: ...Circuit diagrams BR BD 100 250 R BP RI Page 154 171 Service Manual 08 2007 8 2 Circuit diagram 0 088 876 0 Head CPU A1 ...