BR/BD 100/250 R BP / RI
Basic settings and service procedures
Page 87 / 171
Service Manual 08.2007
5.2.1 Access to the test mode
Requirements
- Unit switched off
- Program switch in Pos 1 (drive)
- Key switch (SO) in „O“ position
Display
shutdown takes
a few seconds
Display
Battery:
E....F
Water/C:
E....F
>10s
yes
no
yes
no
Main relay (K1)
switches off
Switch off key switch (SO)
Display
Battery voltage
37,4 V = 2,07 V/Z
fan off:
0,0A
program switch 1-8: 1
Vor:0
USR:0 TR:0
WORK:0
Rund:00
I_traction motor:0,0A
Direction switch
for traction 1 -1
seat switch= 1
gas pedal voltage=0,0V
temp. traction
module: 21°C
I_brush:
0,0A
I_vacuum:
0,0A
I_waterpump:
0,0A
water valve
closed
module temprat.
clean. unit:18°C
switch brush head
upper:0 lower:0
I_linear actuator
Brush head 0,0A
switch squeegee
upper:1 lower:0
I_linear actuator
squeegee 0,0A
temp lift module
clean. unit:23°C
temp. accessory
module:28°C
I_blower, sweep:
0,0A
switch sweep unit:
upper:1 lower:0
I_linear actuator
sweepunit:0,1A
temp. liftmodule
clean.unit: 32°C
-Keep I-button Key function
depressed
and switch on key switch (SO)
Display
self-diagnosis
Self-test
o.k.?
Main relay (K1)
switched on
Display
TESTER MODE ?
Display
Activate module
parameter setup
Display
TESTER-MODE
drives
Display
TESTER-MODE
linear actuators
Display
TESTER-MODE
adjustment
SETUP MENÜ
(see chapter 5.3.2)
TEST MODE
Drive units
(see chapter 5.2.2)
TEST MODE
Lifting motors
(see chapter 5.2.3)
TEST MODE
calibration
(see chapter 5.2.4)
Note:
To quit test mode, switch off the key switch (S0).
Содержание BR 100 R
Страница 1: ...Service Manual 08 2007 5 906 252 0 BR BD 100 250 R RI BR BD 120 250 R RI 1 480 Service Manual ...
Страница 2: ...BR BD 100 250 R BP RI Page 2 171 Service Manual 08 2007 ...
Страница 153: ...BR BD 100 250 R BP RI Circuit diagrams Page 153 171 Service Manual 08 2007 8 1 Circuit diagram 0 088 734 0 Head CPU A1 ...
Страница 154: ...Circuit diagrams BR BD 100 250 R BP RI Page 154 171 Service Manual 08 2007 8 2 Circuit diagram 0 088 876 0 Head CPU A1 ...