Basic settings and service procedures
BR/BD 100/250 R BP / RI
Page 84 / 171
Service Manual 08.2007
5.1.5.1 Accelerator pedal calibration
Requirements
– Unit is ready for service in test mode
– Program switch (S9) in Pos 5 Polish
– Above the rotary function I-button the Calibrate accelerator pedal? display is active
yes
no
Display
Calibrate accelerator
pedal?
yes
no
yes
yes
no
no
no
yes
Display
Release accelerator
pedal?
Do not press both pedals,
must be in the
original position
Then
Display
Floor forwards
accelerator pedal?
Fully floor pedal and hold
Then
Display
Floor accelerator
pedal backwards
Fully floor left pedal and hold
Then
Calibration o.k.?
Display
Accelerator pedal
calibration completed
3s
Display
Difference <500
Min 683 max 688
Display
Calibrate
accelerator: (663)
Display
Skip calibration?
Note:
- Switch off the key switch (S0) to quit test mode