Basic settings and service procedures
BR/BD 100/250 R BP / RI
Page 82 / 171
Service Manual 08.2007
5.1.4 Access to the test mode
(with program switch S9, position 4)
This access is only possible in the following unit versions.
- BR-100/250 R with pre-sweeper and side brush
- BR-100/250 R with side brush
It is inactive in BR 100/250 R basic unit. (no display activity)
Requirements
- Unit switched off
- Program switch (S9) in Pos 4 (vacuum)
- Key switch (SO) in „O“ position
Main relay (K1)
switches off
yes
no
Display
shutdown soon
Switch off key switch (SO)
Display
Battery:
E....F
Water/C:
E....F
Error display
?
Display
Error display
>10s
yes
no
Display
Set TEST
MODE?
Main relay (K1)
is connected
Self-test
o.k.?
Display
BR 100/250R
Self-test
- Hold i-button inch function
and
- Switch on key switch (SO)
no
Pre-sweeper and
side brush?
yes
no
Switch
off all
drives
Side
brush
Brush on/off
Raise brush
head
ES=H
I=0.0A
Lower brush
head
ES=H
I=0.0A
On/Off function or
open/closed see 5.1.2.1
Function notes:
The i-button inch function (con-tinuously press)
activates the component, during the active
period the LED service (yellow) lights up.
When the limit position microswitch (ES) is
reached, the LED goes out and ES=H or L
appears in the display, depending on the
position.
Further, the motor current (I=0.0A) is also
displayed. This value also returns to zero when
the respective limit position (top or bottom) is
reached.
H=top
L=bottom
- =Position undetermined (no limit switch
reached)
Main brush
Brush on/off
Side brush
Brush on/off
Suction fan
Brush on/off
Filter cleaning
Brush on/off
Raise
brush
head
ES=H
I=0.0
Lower
brush
head
ES=H
I=0.0A
Note:
- If the rotary pulse generator is turned in an anti-clockwise direction the cursor acts in the opposite direction, i.e. the menu is
called up from the last to the first parameter. The last saved cursor can be called up again after quitting the menu, e.g. by
switching back to the standard display (battery display).
- Switch off the key switch (S0) to quit test mode
Display
Switch
off all
drives
Display
Содержание BD 100 R
Страница 1: ...Service Manual 08 2007 5 906 252 0 BR BD 100 250 R RI BR BD 120 250 R RI 1 480 Service Manual ...
Страница 2: ...BR BD 100 250 R BP RI Page 2 171 Service Manual 08 2007 ...
Страница 153: ...BR BD 100 250 R BP RI Circuit diagrams Page 153 171 Service Manual 08 2007 8 1 Circuit diagram 0 088 734 0 Head CPU A1 ...
Страница 154: ...Circuit diagrams BR BD 100 250 R BP RI Page 154 171 Service Manual 08 2007 8 2 Circuit diagram 0 088 876 0 Head CPU A1 ...