5.1.3 Access to the test mode
(with program switch S9, position 3)
Function notes:
The i-Button inch function (press continuously) is used to
activate the unit; while it is active the LED service (yellow) is lit.
When the limit position microswitch (ES) is reached, the LED
goes out and ES=H or L appears in the display, depending on
the position.
Further, the motor current (I=0.0A) is also displayed. This
value also returns to zero when the respective limit position
(top or bottom) is reached.
H=Top
L=bottom
- =Position undetermined (no limit switch reached)
Key
- ES Limit switch lifting motor / brush unit
- ES Limit switch lifting motor / suction bar
"Position" mode: Lifting motors with limit switch
- ES-
Lifting motor / brush unit without limit switch
- ES-
Lifting motor / suction bar without limit switch
"Block" mode: Lifting motor is switched off via the overload
current in the blockage phase
Note:
- If the rotary pulse generator is turned in an anti-clockwise direction the cursor acts in the opposite direction, i.e. the menu is
called up from the last to the first parameter. The last saved cursor can be called up again after quitting the menu, e.g. by
switching back to the standard display (battery display).
- Switch off the key switch (S0) to quit test mode
Requirements
- Unit switched off
- Program switch (S9) in Pos 3 (wet scrub without vacuuming)
- Key switch (SO) in „O“ position
Main relay (K1)
switches off
yes
no
Display
shutdown soon
Switch off key switch (SO)
Display
Battery:
E....F
Water/C:
E....F
Error display
?
Display
Error display
>10s
yes
no
Display
Set TEST
MODE?
Main relay (K1)
is connected
Self-test
o.k.?
Display
BR 100/250R
Self-test
- Hold i-button inch function
and
- Switch on key switch (SO)
yes
no
BK raise
Position
ES=H
I=0.0A
SB raise
Position
ES=H
I=0.0A
BK raise
Block
ES=-
I=0.0A
SB raise
Block
ES=-
I=0.0A
BK lower
Position
ES=H
I=0.0A
SB lower
Position
ES=H
I=0.0A
BK lower
Block
ES=-
I=0.0A
SB lower
Block
ES=-
I=0.0A
Содержание BD 100 R
Страница 1: ...Service Manual 08 2007 5 906 252 0 BR BD 100 250 R RI BR BD 120 250 R RI 1 480 Service Manual ...
Страница 2: ...BR BD 100 250 R BP RI Page 2 171 Service Manual 08 2007 ...
Страница 153: ...BR BD 100 250 R BP RI Circuit diagrams Page 153 171 Service Manual 08 2007 8 1 Circuit diagram 0 088 734 0 Head CPU A1 ...
Страница 154: ...Circuit diagrams BR BD 100 250 R BP RI Page 154 171 Service Manual 08 2007 8 2 Circuit diagram 0 088 876 0 Head CPU A1 ...