6.2.4 Head CPU (A1) error messages
Module
Fault
classification
Display code
Action
Head CPU
Forward and
reverse operation
are present at the
same time
K1/163
1. Check function of travel direction switch (S2) (*)
and contact bonding.
2. Check cabling from (S2) to the module (A2) or to
module (A1) for short circuiting to the root.
3. Check correct cabling with (A2) and/or (A1).
4. If error continues, replace A2 and/or (A1).
(*) Connected to (A2) in BR/BD 100-120/250 R/I
(S2).
Malfunction of
parameter buffer
K1/171
1. Software error in process control -> developer:
2. Replace A1 with A1 for new firmware.
Protocol error in
bus transmission
K1/172
1. Perform key switch (S0) reset several times.
2. If errors continue, test single module coupling, for
this, connect head CPU (A1) with only one ran-
dom module as direct bus. If error is replaced by
another, test with other modules until the mal-
functioning module is found. Replace the mal-
functioning module.
3. If the error continues, inform the developer.
4. Replace (A1) with (A1) for new firmware.
Module status
query is not
possible
K1/173
Command buffer
overflow
K1/174
1. Perform key switch (S0) reset.
2. If fault remains, replace A1.
3. Do not activate the program switch continuously,
i.e. do not continuously perform program changes
below 1-2 seconds in the timing code!
Содержание BD 100 R
Страница 1: ...Service Manual 08 2007 5 906 252 0 BR BD 100 250 R RI BR BD 120 250 R RI 1 480 Service Manual ...
Страница 2: ...BR BD 100 250 R BP RI Page 2 171 Service Manual 08 2007 ...
Страница 153: ...BR BD 100 250 R BP RI Circuit diagrams Page 153 171 Service Manual 08 2007 8 1 Circuit diagram 0 088 734 0 Head CPU A1 ...
Страница 154: ...Circuit diagrams BR BD 100 250 R BP RI Page 154 171 Service Manual 08 2007 8 2 Circuit diagram 0 088 876 0 Head CPU A1 ...