Basic settings and service procedures
BR/BD 100/250 R BP / RI
Page 80 / 171
Service Manual 08.2007
5.1.2.1 Current measurement with switching on/off function
Requirements
- Unit is ready for service in test mode
- Program switch (S9) in Pos 2 wet scrub with vacuuming (orPos 1 Drive)
- Above the rotary function I button the display is Suction motor on/off
The current can also be measured
during the functional check
- Brush/roller
- Suction motor
- Main brush
- Broom
- Sweep fan
Note:
Switch off the key switch (S0) to quit test mode.
Switch program switch (S9)
to Pos 2
(wet scrub with vacuuming)
Display
I_Suction
motor
yes
no
Last selected component
display
Switch program switch
(S9) to Pos 1 (Drive)
no
yes
Measure
current?
- Suction motor on service
-Yellow LED service active
Display
Suction motor
on/off
no
yes
Display
Suction motor
on/off
- Suction motor shutdown
-Yellow LED service inactive
yes
no