Basic settings and service procedures
BR/BD 100/250 R BP / RI
Page 96 / 171
Service Manual 08.2007
5.3 Setup menu
5.3.2.2 System menu and driving module parameters
Display
Activate module
parameter setup
(flashing)
Lifting module
(See Chapter
5.3.2.3)
Display
parameter menu
traction module?
yes
no
yes
no
no
yes
no
yes
yes
no
no
yes
Display
return to SETUP
module selection?
Display
return to SETUP
module selection?
Display
parameter menu
system module?
Access to
SETUP MENU
(See Chapter 5.3.2.1)
Access to
SETUP MENU
(See Chapter 5.3.2.1)
Note:
If the i-button is not pressed for 30 seconds the program automatically switches back to
Activate parameter setup module
(flashing)
The unit must then be restarted as described in Chapter 5.3.2.1.
Change and save PARAMETERS
(See Chapter 5.3.3)
Display
Display
sel. language: 0
0=German
1=Engl.
scrubber model
BR/BD-100/250R
beacon active du
ring reversion = 0
time to standby:30 Min
min. DOD-voltage.
32,4V = 1,8V/Z
minimum brush
pressure:
40A
move brushhead: 1
0 = switch
1= bloc
on-time shaker
sweep unit: 10s
off-time shaker
sweep unit: 120s
show warnig mes
y = 0
n = 1
agent metering
on = 1
off = 0
ophr:
0h 00m
restoring: 0
initiate calibration
of gas pedal
max-forward
speed:
6,0 km/h
max-reverse
speed:
3,5 km/h
accel. ramp: 2
decel. ramp: 2
creep speed:
0,4 km/h
max motor
current:
125A
max braking
current:
125A
reset voltage
37,8V
=
2,1V/Z
Содержание BD 100 R
Страница 1: ...Service Manual 08 2007 5 906 252 0 BR BD 100 250 R RI BR BD 120 250 R RI 1 480 Service Manual ...
Страница 2: ...BR BD 100 250 R BP RI Page 2 171 Service Manual 08 2007 ...
Страница 153: ...BR BD 100 250 R BP RI Circuit diagrams Page 153 171 Service Manual 08 2007 8 1 Circuit diagram 0 088 734 0 Head CPU A1 ...
Страница 154: ...Circuit diagrams BR BD 100 250 R BP RI Page 154 171 Service Manual 08 2007 8 2 Circuit diagram 0 088 876 0 Head CPU A1 ...