CAN RANGER III INSTALLATION
20
International
Mercedes
Bump Throttle
Cruise Control
On Off Throttle
PWM
Inverted PWM
Analog
Actuator
Press the
←
arrow button if
you don’t want to change the
RPM setting and return to
Calibration Menu or press
<SET> to select and save.
Caterpillar, Cummins,
International, and Mercedes
all have pre-set configurations
and settings. If you have one
of these engines, pick the
appropriate one. Then you
can fine tune the settings to
match what your vehicle
needs. The parameters are
MINIMUM RPM (Idle),
MAXIMUM RPM (Full throttle)
and for Caterpillar,
FREQUENCY.
Bump Throttle sends a pulse
to ECM through RPM+ output
which increments the engine
RPM to the next sequential
setting. These are set in the
engine, not in the Ranger III
unit.
Cruise Control and On Off
Throttle use 2 On/Off
outputs (Floating or
) for increasing or
decreasing the RPM. These
outputs will connect
to outputs RPM-
and RPM+ when the
corresponding buttons are
pressed on the transmitter.
Note: If you need sinking
signals to your engine, use 2
relays to invert these outputs.