CAN RANGER III INSTALLATION
12
The receiver will not let
you add more than one
at a time.
The receiver cannot
know if you are assigning
the wrong ID to an
actuator. That is, if you
attach the BOOM
actuator and tell the
receiver it is the WINCH,
the receiver will treat
that actuator as the
WINCH and the crane
will not operate correctly.
If you skip an actuator
during the assignment
process, the Receiver will
not know, and will not
assign that actuator.
After assigning IDs, you
need to re-calibrate the
actuators, or at least any
new or swapped
actuators.
Leave the actuators
plugged in after you add
each one. No need to
remove them after each
step. If you do remove
an actuator that has
been assigned and you
still need to assign other
actuators. Do not plug
the taught actuator back
in until you have
completed the ID Assign
procedure and exited.
If you leave the
actuators mechanically
linked to the valves
during the ID step, the
actuator’s ZERO position
may not be correct. If
you get strange/incorrect
position readings, this
may be the reason.
ACTUATOR CALIBRATION