CAN RANGER III INSTALLATION
10
and labeled for each function.
The following procedure is
only if reassignment is
required in case of actuator
replacement or if two identical
actuators are detected.
Note: If the receiver ever
detects two or more
actuators with the same
ID, it will stop operation
and indicate errors. The
receiver tests for this
every time it is powered up
and continually as it runs.
Since all actuators are
identical, they need to be
assigned identification
numbers by the receiver in
order to distinguish which
actuator does what function.
Using the buttons on the CAN
Ranger Receiver, navigate
through the screens to
CALIBRATION. Press <SET>.
Use the arrow buttons to
enter the password 1262.
Enter the password by
pressing <SET>. Then select
ASSIGN ACTUATORS from
menu by pressing <SET>.
Use the
←
arrow button to
return to Calibration Menu or
<MENU> button to return to
the Main Menu.
NOTE: ACTUATOR 2-8
functions are deactivated
by default. If you want to
use these functions, you
must enable them first
before assigning the
actuators see OPTION
SETUP.