4 Release the DC and AC cables from the connection terminals.
5 Open the cable fittings.
6 Pull out the cables.
»
The device is uninstalled. Proceed with disassembly.
14.4
Disassembling the device
↻
Unit has been switched off and uninstalled.
1 Remove the screw that prevents the device from being lifted off the mount.
2 Use the lateral openings and lift the device off the mount.
»
Device removed. Proceed with the packaging process.
14.5
Packaging the device
↻
Device has been uninstalled.
1 If possible, always pack the device in the original packaging. If this is no longer available, an alternative is to use equi-
valent packaging.
2 You must be able to close the box completely and it must be able to accommodate the weight and size of the device.
14.6
Storing the device
NOTE
Property damage as a result of condensation
Faulty storage can form condensate in the device and impair the device functioning (e.g. storage outside
the ambient conditions or temporary relocation from a cold to a hot environment).
›
Prior to installation, check the inner area for condensation and if necessary, allow it to dry sufficiently
before installation.
›
Store in accordance with the technical data > Environmental data [See section 4.3
↻
Device packaged.
F
Powador 30.0-72.0 TL3
Page 85