![Kaco 1000335 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/kaco/1000335/1000335_manual_649206006.webp)
1.4
Identification
You will find the name plate with the following data for service and other require-
ments specific to installation on the right side panel of the product:
Product name
Part no.
Serial number
Date of manufacture
Technical data
Disposal information
Certification marking, CE marking.
Typ / Type
Powador 39.0 TL3 - XL - F -
INT
Seriennummer
/ serial no.
000000000123456789
KACO new energy GmbH
Artikelnummer
/ part no.
1001022
Carl-Zeiss-Str. 1
74172 Neckarsulm
MADE IN GERMANY
Max. Eingangsleistung / input power DC
39000 W
Max. Eingangsstrom / input current DC / Isc PV
3 x 34 A | 3 x 40,8 A
Max. Eingangsspannung / input voltage DC
1000 V
Min. Eingangsspannung / input voltage DC
200 V
MPP-Spannungsbereich / MPP voltage range DC
340 - 800 V
Umgebungstemperatur / ambient temperature
-20 °C ... +60 °C
Schutzklasse | Schutzart / protection class | protection
1 / IP54
Cos phi
1-0,3 ind/cap
Nennspannung / rated output voltage AC
400 V / 230 V 3/N/PE
Frequenz / rated frequency
50 Hz / 60 Hz
Nennleistung DE / rated output power AC INT
33300 VA
Nennstrom DE / rated output current AC INT
48,3 A
Netzüberwachung / grid monitoring
VDE V 0126-1-1 + A1 / country specific
Jahr / year
Q3 / 2019
galvanisch nicht getrennt / no galvanic isolation
Dep. on country settings all specific requirements are
met, details see manual.
Fig. 1:
Name plate
1.5
Warnings on the device
A warning sticker is affixed to the device. Read the warnings carefully.
Do not remove the sticker. If the sticker is missing or is illegible, please contact a
KACO representative or distributor.
Article number: 22000270
Fig. 2:
Warning sticker
1.6
Target group
All activities described in the document may only be carried out by specially trained personnel with the following qualific-
ations:
Knowledge about how an inverter functions and operates
Knowledge about IP-based network protocols
Knowledge of the Modbus specifications
Knowledge of the SunSpec Modbus specifications
Education concerning the installation and configuration of IT systems
Training in the handling of hazards and risks during the installation and operation of electrical devices and systems.
Education concerning the installation and start-up of electrical units and plants.
Knowledge of applicable standards and directives.
Knowledge and adherence to this document with all safety notices.
Powador 30.0-72.0 TL3
Page 6
EN