Page 27
Con
tr
olling y
our ZLM1
© JVA Technologies Pty. Ltd. www.jva-fence.com
JVA ZLM1 Manual
8.6.6
To Clear Alarm Memory
After an alarm occurs, pressing *1#, will clear the alarm memory. If the
problem still exists the unit will alarm again.
8.6.7
Changing the PIN Number
•
Enter the old PIN (default is 1234) and press *0#. This enters User Pro
-
gramming mode.
•
Enter your new PIN (must be 4 digits) and then #. (Repeat to confirm
PIN.)
• Press *# to exit User Programming mode.
•
Make sure your new PIN works by using it to arm the energiser or mon
-
itor.
Содержание ZLM1
Страница 1: ...Single Zone Low Voltage Monitor ZLM1 User Manual JVA TECHNOLOGIES www jva fence com...
Страница 5: ...Page 5 JVA ZLM1 Manual Contents...
Страница 11: ...Page 11 Introduction JVA ZLM1 Manual...
Страница 50: ...Technical Information Page 50 JVA Technologies Pty Ltd www jva fence com...
Страница 51: ...Page 51 Technical Information JVA ZLM1 Manual DEALER...
Страница 52: ...www jva fence com...