Page 15
Specifica
tions
© JVA Technologies Pty. Ltd. www.jva-fence.com
JVA ZLM1 Manual
5
SPECIFICATIONS
The specifications table below outlines the power consumption of the
ZLM1 and the acceptable voltage and current ranges for different inputs
and outputs.
Nominal input voltage
14.2Vdc
Power consumption of ZLM1 (Note
1)
63mA at 12.5 Vdc
Maximum voltage on “In1” input
(Note 2)
5Vdc
Maximum Energiser Joules (Note 3)
18J
Maximum loop impedance
5000 Ohm
Maximum loop capacitance to
ground
1.0uF
Minimum loop resistance to ground 1000 Ohm
Maximum external HV measure-
ment voltage (Note 4)
10,000v
NOTE 1
: This is the power consumption when none of the powered outputs
are active and the keypad is not connected. The rated power consumption
may be lower depending on relay configuration and alarm states.
NOTE 2:
The control inputs as supplied with 5V from a “weak pull up”
circuit so that they can be controlled using dry contacts from a relay or
switch. A device with “open collector” outputs may be used. They can also