11.3.5
Chime mode (14x#)
This option allows the keypad beeper to be used as a door chime for the
gate switch.
When set to None, the keypad beeper is used to indicate correct keypad
operation only.
The Door Chime is
NOT
used.
The Siren is
NOT
used.
The Gate beeps plus Siren is
NOT
used.
Value
Function
0
None
1
Door Chime
2
Siren
3
Fence Alarm
4
Gate beeps plus Siren
11.3.6
Auto Re-Arm time (20x#)
This option sets the time which must elapse before another alarm will
sound after the first alarm has timed out (gone completely through its
cycles).
If an event occurs which triggers an alarm, any other events which would
otherwise trigger the alarm will be ignored while the alarm is sounding and
until after the Auto re-arm time has passed.
A setting of 9 will disable auto re-arm.
The default is 0 Seconds (Immediate).
Value (x)
Function
0
0 Seconds
(immediate)
1
30 Seconds
2
1 Minutes
3
2 Minutes