© JVA Technologies Pty. Ltd. www.jva-fence.com
8.6.8
Internal Beeper/Keypad Beeper
Depending on the Chime Mode setting, the internal beeper and keypad
beeper will sound when there is a fence alarm, a gate alarm, a general
alarm or a door chime. On flat battery the keypad will always beep 4 times
before the energiser or monitor automatically enters low power mode to
preserve the battery.
Note: The Internal beeper also beeps at Power up.
8.6.9
ZLM1 Relevant Keypad Codes
The default user pin is 1234. The default installer pin is 012345.
Function
Key Sequence
Arm/Disarm
[User PIN][#]
Silence an alarm (Single zone
system only)
[User PIN][#]
Start Programming the Z-Series en-
ergiser or monitor
[Installer PIN][*] [0] [#]
Start Programming the
Keypad
[Installer PIN][*] [0] [1] [#]
Exit Programming (any
mode)
[*] [#]
Change a User PIN
[User PIN][*][0][#][New PIN]#
Change the Installer PIN
[0] [0] [New Installer PIN][#]
Arm All Zones (Multi-zone
groups)
[User PIN][*][1][0][#]
Arm Zone 1 (Master)
[User PIN][*][1][1][#]
Arm Zone x, where x is
any zone number up to 15
[User PIN][*][1][x][#]
Disarm All Zones
[User PIN][*][2][0][#]
Disarm HV Zone 1 or Master
[User PIN][*][2][1][#]
Содержание ZLM1
Страница 1: ...Single Zone Low Voltage Monitor ZLM1 User Manual JVA TECHNOLOGIES www jva fence com...
Страница 5: ...Page 5 JVA ZLM1 Manual Contents...
Страница 11: ...Page 11 Introduction JVA ZLM1 Manual...
Страница 50: ...Technical Information Page 50 JVA Technologies Pty Ltd www jva fence com...
Страница 51: ...Page 51 Technical Information JVA ZLM1 Manual DEALER...
Страница 52: ...www jva fence com...