Function
Logic for alarm state (opposite of normal state)
Zone 1
Alarm
The ZLM1 is Armed AND
Any zone alarm occurs, these include:
The loop return Voltage has fallen below the Fence
Voltage Alarm Level (Low Voltage)
High voltage has been detected (shorted to high volt-
age wires)
For more Energiser pulses than the Missed Pulse Count
setting. Not latched.
Armed
The ZLM1 is Armed
General
Tamper OR Low Battery OR Internal Error. Latched for in
-
ternal errors only.
Battery
Alarm on low or bad input voltage
11.3.8
Group Mode (26x#)
A group must have only 1 master. The other Energisers/Monitors in the
group are slaves.
The correct procedure is:
Connect the keypad to each Energiser/ZLM1 in turn, programming each
Option as required before linking the Keypad bus into a group.
The ZLM1 should only be a group master if there are no Z energisers in the
group. I.e. the group is made up of one or more ZLM1 units only.
If a PAE212 TCP/IP adaptor is used, it is the group master. All other devices
should be set to slaves.
All energisers must be synchronised, therefore non-synchronised agricul
-
tural energiser must never be used in a system with a ZLM1. This allows the
ZLM1 pulses to be synchronised with other ZLM1 units or Z-Series Energis
-
ers.
Value (x)
Mode
0
No Group
Содержание ZLM1
Страница 1: ...Single Zone Low Voltage Monitor ZLM1 User Manual JVA TECHNOLOGIES www jva fence com...
Страница 5: ...Page 5 JVA ZLM1 Manual Contents...
Страница 11: ...Page 11 Introduction JVA ZLM1 Manual...
Страница 50: ...Technical Information Page 50 JVA Technologies Pty Ltd www jva fence com...
Страница 51: ...Page 51 Technical Information JVA ZLM1 Manual DEALER...
Страница 52: ...www jva fence com...