11. Power on the services gateway. The OK LED on the power supply faceplate should blink, then light
steadily.
12. Verify that the MPC and MICs are functioning correctly by issuing the show chassis fpc and show
chassis fpc pic-status commands.
Replacing SRX5600 Services Gateway Port Modules
To replace a port module, perform the following procedures:
1.
Removing an SRX5600 Services Gateway Port Module | 333
2.
Installing an SRX5600 Services Gateway Port Module | 335
Removing an SRX5600 Services Gateway Port Module
Port modules are installed in Flex IOCs in the services gateway card cage. A port module weighs up to
1.6 lb (0.7 kg). Be prepared to accept its full weight when you remove or install a port module.
To remove a port module (see
1. Have ready a replacement port module or blank panel and an antistatic mat for the port module. Also
have ready rubber safety caps for each port on the port module you are removing that uses an optical
interface.
2. Wrap and fasten one end of the ESD grounding strap around your bare wrist, and connect the other
end of the strap to the ESD point on the chassis.
3. Label the cables connected to each port on the port module so that you can later reconnect the cables
to the correct ports.
4. Use one of the following methods to take the port module offline:
•
Insert a pointed tool into the ONLINE pinhole on the front panel of the port module to press the
button behind it. Hold the button down until the OK/FAIL LED goes off.
•
Issue the following CLI command:
user@host>
request chassis fpc-slot
slot-number
pic-slot
slot-number
offline
For more information about the command, see Junos OS System Basics and Services Command Reference
at
www.juniper.net/documentation/
.
333
Содержание SRX5600
Страница 1: ...SRX5600 Services Gateway Hardware Guide Published 2020 02 14 ...
Страница 23: ......
Страница 105: ...LEDs 106 ...
Страница 114: ...Figure 51 SRX5K MPC g030309 MPC empty 115 ...
Страница 124: ...Port and Interface Numbering 125 ...
Страница 130: ...Port and Interface Numbering 131 ...
Страница 156: ......
Страница 183: ...Table 54 RJ 45 Connector Pinout for the AUX and CONSOLE Ports continued Description Signal Pin Clear to Send CTS 8 185 ...
Страница 185: ......
Страница 193: ...Figure 84 Installing the Front Mounting Hardware for a Four Post Rack or Cabinet 196 ...
Страница 239: ......
Страница 285: ...c Upload the configuration to RE2 from the USB device 288 ...
Страница 372: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5600 377 ...
Страница 373: ......
Страница 407: ......
Страница 420: ...423 ...
Страница 423: ...Restricted Access Area Warning 426 ...
Страница 430: ...433 ...
Страница 443: ...Jewelry Removal Warning 446 ...
Страница 446: ...Operating Temperature Warning 449 ...
Страница 456: ...DC Power Disconnection Warning 459 ...
Страница 460: ...DC Power Wiring Sequence Warning 463 ...
Страница 463: ...DC Power Wiring Terminations Warning 466 ...
Страница 466: ...DC Power Disconnection Warning 469 ...
Страница 470: ...DC Power Wiring Sequence Warning 473 ...
Страница 473: ...DC Power Wiring Terminations Warning 476 ...