If a slot in the SRX5400, SRX5600, or SRX5800 Services Gateway card cage is not occupied by a card,
you must install a blank panel to shield the empty slot and to allow cooling air to circulate properly through
the services gateway.
•
Fixed-configuration IOC with forty 10-Gbps port speeds
•
Maximum throughput: 400-Gbps
•
Maximum configurable MTU: 9192 bytes
Description
Junos OS Release 19.3R1 and later
Software release
•
SRX5400—Any slot, except the bottom slots 0 and 1/0,
which are reserved for SCB/RE.
NOTE:
Slot 1/0 is a dual purpose slot. You can install
SRX5K-IOC4-10G in slot 2/6 if an SCB is not already
installed in it.
•
SRX5600—Any slot, except the bottom slots 0 and 1,
which are reserved for SCB/RE.
•
SRX5800—Any slot, except the middle slots 0, 1, and
2/6, which are reserved for SCB/RE, and slots 0 (most
left) and 11 (most right).
NOTE:
Slot 2/6 is a dual purpose slot. You can install
SRX5K-IOC4-10G in slot 2/6 if an SCB is not already
installed in it.
Supported slots
See
for the transceivers
supported.
Cables and connectors
•
Typical: 405 W
At different temperatures:
•
131° F (55° C): 500 W
•
104° F (40° C): 465 W
•
75° F (25° C): 430 W
Power requirements
17 lb (7.7 kg)
Weight
138
Содержание SRX5600
Страница 1: ...SRX5600 Services Gateway Hardware Guide Published 2020 02 14 ...
Страница 23: ......
Страница 105: ...LEDs 106 ...
Страница 114: ...Figure 51 SRX5K MPC g030309 MPC empty 115 ...
Страница 124: ...Port and Interface Numbering 125 ...
Страница 130: ...Port and Interface Numbering 131 ...
Страница 156: ......
Страница 183: ...Table 54 RJ 45 Connector Pinout for the AUX and CONSOLE Ports continued Description Signal Pin Clear to Send CTS 8 185 ...
Страница 185: ......
Страница 193: ...Figure 84 Installing the Front Mounting Hardware for a Four Post Rack or Cabinet 196 ...
Страница 239: ......
Страница 285: ...c Upload the configuration to RE2 from the USB device 288 ...
Страница 372: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5600 377 ...
Страница 373: ......
Страница 407: ......
Страница 420: ...423 ...
Страница 423: ...Restricted Access Area Warning 426 ...
Страница 430: ...433 ...
Страница 443: ...Jewelry Removal Warning 446 ...
Страница 446: ...Operating Temperature Warning 449 ...
Страница 456: ...DC Power Disconnection Warning 459 ...
Страница 460: ...DC Power Wiring Sequence Warning 463 ...
Страница 463: ...DC Power Wiring Terminations Warning 466 ...
Страница 466: ...DC Power Disconnection Warning 469 ...
Страница 470: ...DC Power Wiring Sequence Warning 473 ...
Страница 473: ...DC Power Wiring Terminations Warning 476 ...