Unmounting file systems: [ OK ]
init: Re-executing /sbin/init
Halting system...
System halted.
CAUTION:
The final output of any version of the request vmhost halt command is
the System halted.. Wait at least 60 seconds after first seeing this message before
following the instructions in Step
and Step
to power off the router.
3. Wrap and fasten one end of an ESD strap around your bare wrist, and connect the other end of the
strap to the ESD point on the chassis.
4. To disconnect power to the router:
•
AC power supply—Set the enable switch to the OFF (O) position and gently pull out the coupler for
the power cord from the faceplate.
•
DC power supply—Switch the circuit breaker on the panel board that services the DC circuit to the
OFF position.
5. Remove the power source cable from the power supply faceplate:
•
AC power supply—Remove the power cord from the power supply faceplate by detaching the power
cord retainer and gently pulling out the male end of the power cord connected to the power supply
faceplate.
•
DC power supply—Loosen the thumbscrews securing the DC power connector on the power source
cables. Remove the power source cables from the power supply faceplate.
6. Uncable the router before removing it from the rack.
Removing an MX10016 Router From a Four-Post Rack Using a Mechanical
Lift
Because of the size and weight of the router, we strongly recommend using a mechanical lift to remove
the MX10016.
Before you remove the router using a lift:
240
Содержание MX10016
Страница 1: ...MX10016 Universal Routing Platform Hardware Guide Published 2019 10 15 ...
Страница 19: ......
Страница 86: ......
Страница 123: ......
Страница 153: ......
Страница 239: ...Figure 118 Moving the MX10016 Using a Mechanical Lift g100421 242 ...
Страница 240: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 245 Alarm Messages 249 ...
Страница 241: ......
Страница 249: ......
Страница 277: ...Restricted Access Warning 281 ...
Страница 292: ...Jewelry Removal Warning 296 ...
Страница 295: ...Operating Temperature Warning 299 ...
Страница 304: ...DC Power Disconnection Warning 308 ...
Страница 308: ...DC Power Wiring Sequence Warning 312 ...
Страница 311: ...DC Power Wiring Terminations Warning 315 ...
Страница 320: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 324 ...