MX10016 Component Redundancy
The MX10016 router is designed so that no single point of failure can cause the entire system to fail. The
following major hardware components in the redundant configuration provide redundancy:
•
Routing and Control Board (RCB)—The RCB consolidates the Routing Engine function with the control
plane function in a single unit. The MX10016 router can have one RCB in a base configuration or two
RCBs in a redundant configuration. When two RCBs are installed, one functions as the master and the
other functions as the backup. If the master RCB (or either of its components) fails, the backup can take
over as the master. See
“MX10016 Routing and Control Board” on page 75
•
Switch Fabric Boards (SFBs)—The MX10016 router has six SFB slots. Five SFBs are required for base
operation and the sixth SFB provides n+1 redundancy. All six SFBs are active and can sustain full
throughput rate. The fabric plane can tolerate one SFB failure without any loss of performance. See
“MX10016 Switch Fabric Board” on page 80
.
•
Power supplies—The MX10016 router requires three power supplies for minimum operation. Additional
power supplies, provide n+1 redundancy for the system. AC, DC, HVAC, and HVDC systems tolerate a
single power supply to fail without system interruption. If one power supply fails in a fully redundant
system, the other power supplies can provide full power to the MX10016 router indefinitely.
The MX10016 router also supports source redundancy. Two sets of lugs are provided for the
JNP10K-PWR-AC cables, four sets of lugs are provided for the JNP10K-PWR-DC2 cables, and two AC
power cords are provided for each JNP10K-PWR-AC2 power supply.
•
Cooling system—The fan trays have redundant fans, which are controlled by the fan tray controller. If
one of the fans fails, the host subsystem increases the speed of the remaining fans to provide sufficient
cooling for the router indefinitely. See
“MX10016 Cooling System” on page 44
.
MX10016 Hardware and CLI Terminology Mapping
This topic describes the hardware terms used in MX10016 router documentation and the corresponding
terms used in the Junos OS CLI. See
.
Table 5: CLI Equivalents of Terms Used in Documentation for MX10016 Routers
Additional Information
Item in
Documentation
Value (CLI)
Description (CLI)
Hardware
Item (CLI)
Router chassis
–
JNP10016
[MX10016]
Chassis
33
Содержание MX10016
Страница 1: ...MX10016 Universal Routing Platform Hardware Guide Published 2019 10 15 ...
Страница 19: ......
Страница 86: ......
Страница 123: ......
Страница 153: ......
Страница 239: ...Figure 118 Moving the MX10016 Using a Mechanical Lift g100421 242 ...
Страница 240: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 245 Alarm Messages 249 ...
Страница 241: ......
Страница 249: ......
Страница 277: ...Restricted Access Warning 281 ...
Страница 292: ...Jewelry Removal Warning 296 ...
Страница 295: ...Operating Temperature Warning 299 ...
Страница 304: ...DC Power Disconnection Warning 308 ...
Страница 308: ...DC Power Wiring Sequence Warning 312 ...
Страница 311: ...DC Power Wiring Terminations Warning 315 ...
Страница 320: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 324 ...