Table 38: Physical Specifications for a JNP10K-PWR-AC2 Power Supply (continued)
Value
Specification
15.1 in. (38.35 cm)
Depth
15.1 in. (38.35 cm)
Weight
MX10016 Power Cord Specifications
IN THIS SECTION
JNP10K-PWR-AC Power Cable Specifications | 105
JNP10K-PWR-AC2 Power Cable Specifications | 107
JNP10K-PWR-AC2 Power Cable Specifications for 30-A Input | 110
Each AC power supply has two independent 16 A rated AC inlets on the faceplate. Most sites distribute
power through a main conduit that leads to frame-mounted power distribution panels, one of which can
be located at the top of the rack that houses the router. An AC power cord connects each power supply
to the power distribution panel.
Each detachable AC power cord is 8 feet (approximately 2.5 meters) long. The appliance coupler at the
female end of the cord inserts into the AC appliance inlet on the faceplate of the AC power supply. The
coupler type is C19 as described by the International Electrotechnical Commission (IEC) standard 60320.
The plug at the male end of the power cord fits into the power source outlet that is standard for your
geographical location.
NOTE:
In North America, AC power cords must not exceed 15 feet (approximately 4.5 meters) in
length, to comply with National Electrical Code (NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52
and Canadian Electrical Code (CEC) Section 4-010(3). The cords shipped with the router to North
America and Canada are in compliance.
MX10000 AC, high voltage alternating current (HVAC), and high voltage direct current (HVDC) have
specific cord requirements. Use the following sections to determine the cable requirements based on the
model of your power supply and any mode settings:
104
Содержание MX10016
Страница 1: ...MX10016 Universal Routing Platform Hardware Guide Published 2019 10 15 ...
Страница 19: ......
Страница 86: ......
Страница 123: ......
Страница 153: ......
Страница 239: ...Figure 118 Moving the MX10016 Using a Mechanical Lift g100421 242 ...
Страница 240: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 245 Alarm Messages 249 ...
Страница 241: ......
Страница 249: ......
Страница 277: ...Restricted Access Warning 281 ...
Страница 292: ...Jewelry Removal Warning 296 ...
Страница 295: ...Operating Temperature Warning 299 ...
Страница 304: ...DC Power Disconnection Warning 308 ...
Страница 308: ...DC Power Wiring Sequence Warning 312 ...
Страница 311: ...DC Power Wiring Terminations Warning 315 ...
Страница 320: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 324 ...