Table 10: Fan Tray Controller Specifications (continued)
JNP10016-FTC2
JNP10016-FAN-CTRL
Specification
1.5 in. (3.81 cm)
1.5 in. (3.81 cm)
Height
6.5 in. (15.24 cm)
6.5 in. (15.24 cm)
Width
9.4 in. (23.88 cm)
9.3 in. (23.62 cm)
Depth
2.3 lb (1.04 cm)
1.5 lb (0.68 kg)
Weight
Airflow Direction in an MX10016
The air intake to cool the chassis is located on the port (line card) side of the chassis. Air flows into the
chassis from the ports in the Control Boards and line cards, through the Switch Fabric Boards (SFBs), and
exits from the fan trays and the power supplies. This airflow is called port-to-FRU cooling or airflow out
(AFO). See
Figure 20: Airflow Through an MX10016