Setting procedure for trucks with and without indicator instrument (CANDIS (
o
)):
– Enter the three-digit parameter number and confirm with Set key (16).
– The indicator instrument (CANDIS (
o
)) continues to display the operating hours. If
the display changes, cancel the setting procedure with the
o
-key (20) and restart
from the beginning.
– Enter or change the setting value according to the parameter list and confirm with
Set key (16).
Z
When the input is incorrect, the LED (15) of the
o
-key (20) lights up red. After enter-
ing the parameter number again, the setting value can be entered or changed.
Repeat the procedure to enter further parameters. To terminate the input, press the
o
-key (20).
The following parameters can be entered:
Code lock parameter list
No.
Function
Range
Setting value
Default
Setting
value
Comments
Work flow
Code lock
000 Change master code
The length of the master
code (4 to 6 digits) also
determines the length (4
to 6 digits) of the operator
code. As long as operator
codes have been
programmed, only new
codes with the same
length can be entered. If
the code length is to be
changed, all operator
codes must be deleted
first.
0000 - 9999
or
00000 - 99999
or
000000 - 999999
7295
(LED 17 flashes)
Enter the current
code
confirm (Set)
(LED 18 flashes)
Enter a new code
confirm (Set)
(LED 19 flashes)
Repeat new code
Confirm (Set)
001 Add operator code
(max. 600)
0000 - 9999
or
00000 - 99999
or
000000 - 999999
2580
(LED 18 flashes)
Enter a code
confirm (Set)
(LED 19 flashes)
Repeat the code en-
try
Confim (Set)
0606
.GB
E 14
Setting procedure for trucks with and without indicator instrument (CANDIS (
o
)):
– Enter the three-digit parameter number and confirm with Set key (16).
– The indicator instrument (CANDIS (
o
)) continues to display the operating hours. If
the display changes, cancel the setting procedure with the
o
-key (20) and restart
from the beginning.
– Enter or change the setting value according to the parameter list and confirm with
Set key (16).
Z
When the input is incorrect, the LED (15) of the
o
-key (20) lights up red. After enter-
ing the parameter number again, the setting value can be entered or changed.
Repeat the procedure to enter further parameters. To terminate the input, press the
o
-key (20).
The following parameters can be entered:
Code lock parameter list
No.
Function
Range
Setting value
Default
Setting
value
Comments
Work flow
Code lock
000 Change master code
The length of the master
code (4 to 6 digits) also
determines the length (4
to 6 digits) of the operator
code. As long as operator
codes have been
programmed, only new
codes with the same
length can be entered. If
the code length is to be
changed, all operator
codes must be deleted
first.
0000 - 9999
or
00000 - 99999
or
000000 - 999999
7295
(LED 17 flashes)
Enter the current
code
confirm (Set)
(LED 18 flashes)
Enter a new code
confirm (Set)
(LED 19 flashes)
Repeat new code
Confirm (Set)
001 Add operator code
(max. 600)
0000 - 9999
or
00000 - 99999
or
000000 - 999999
2580
(LED 18 flashes)
Enter a code
confirm (Set)
(LED 19 flashes)
Repeat the code en-
try
Confim (Set)
Содержание EJE 116
Страница 1: ...1 2 3 4 5 6 7 8 9 0 Set Operating instructions 50425855 EJE 116 118 120 G 10 03 06 06...
Страница 3: ...0108 GB...
Страница 7: ...0506 GB 2...
Страница 9: ...0600 GB A 2...
Страница 13: ...0803 GB B 4 h 13 Ast l1 l2 Q 150 40 1268 803 h 3 55 y c l a _ 2 a _ 2 700 b 5 b 11 e Wa...
Страница 17: ...0803 GB B 8...
Страница 21: ...0606 GB C 4...
Страница 32: ...E 3 0606 GB 1 2 3 4 5 6 7 8 0 9 S e t 5 4 3 2 1 6 7 12 8 8 9 11 10...
Страница 63: ...0606 GB F 12...
Страница 81: ...0506 GB 18...