11 Technical data
88
c
The accuracy specifications refer to the maximum measuring range.
11.1.4 Resistance transmitter
d
The accuracy specifications refer to the maximum measuring range.
Limits according to NAMUR recommendation NE 43 in case of deviation under/above measuring
range
Signal type 4 to 20 mA
Measurement information M
3.8 to 20.5 mA
Failure information A for deviation below measured value/short circuit ("NAMUR Low")
≤
3.6 mA
Failure information A for deviation above measured value/probe break ("NAMUR High")
≥
21 mA
Designation
Measuring range
Measuring accura-
cy
d
Ambient temperature
influence
Resistance transmitter
≤
400
Ω
±0.4
Ω
≤
±0.01 % per K
deviation from 22 °C
Resistance transmitter
400 to 4000
Ω
±4
Ω
≤
±0.01 % per K
deviation from 22 °C
Resistance transmitter
4000 to 10000
Ω
±10
Ω
≤
±0.01 % per K
deviation from 22 °C
Connection type
3-wire circuit
Sensor line resistance
Max. 50
Ω
per line
Resistance values
Freely programmable within the limits in steps of 0.1
Ω
Special features
Measuring range scaling adjustable
Содержание dTRANS T06 Ex
Страница 16: ...3 Mounting 16 3 Mounting 3 1 Dimensions...
Страница 30: ...5 Starting operation of the device 30 Here is a summary of the parameters from the figure above...
Страница 31: ...5 Starting operation of the device 31...
Страница 67: ...8 IECEx 67...
Страница 106: ...15 Certificates 106 15 Certificates...
Страница 111: ...15 Certificates 111 15 2 SIL and PL...
Страница 112: ...15 Certificates 112 15 3 ATEX...
Страница 113: ...15 Certificates 113...
Страница 114: ...15 Certificates 114...
Страница 121: ......
Страница 122: ......
Страница 123: ......